// products · compare

Eight products,
one table.

Typical values from the datasheets. Pick by the rule you have to satisfy — or by the gas — then open the product page for the full specification.

ShareLinkedInEmailWhatsAppX
Compare
ProductLevelMeasuredRangeResponseOutputs / protocolsEnclosure / ExCalibrationDatasheet
IR·OEM
OEM NDIR channel · one gas or several · board / bench / transmitter
L1 · OEM channelCO₂ · CO · CH₄ · C₂H₄ · N₂O · SO₂ · NH₃ · SF₆ · SO₂F₂ · CH₃Br · biogas (CH₄/CO₂)CO₂ 100 ppm → 100 vol% · CO 2000 ppm → 100 vol% · CH₄ 2000 ppm → 100 vol% · SF₆ 50 ppm → 100 vol% · N₂O / SO₂ / C₂H₄ / NH₃ 200 ppm → 1 vol%LOD 2 % FS · linearity ±2 % · T90 < 30 s · cross-sensitivity < 4 %Modbus RTU / TCP · Ethernet · UART · RS-232/485 · CAN · LoRa · 4–20 mAtraceable ISO 17025 method · VSL · record per unitspec per project
DM-91
multifunction density transducer · SF₆
L2 · field instrumentSF₆ · N₂ · CF₄ · O₂ · CO₂ · Novec™ 4710 · He · Ar · mixtures0.6 / 1.2 / 1.6 / 2.2 MPa abs · 3-year calibration interval±0.2 % URL pressure/density · ±0.2 °C · ±5 % RHRS-485 Modbus RTU · LCD opt. · M12 / cableIP68 · ≤30×125 mm · ≤0.5 kg · −60…+85 °Crecord per unit, traceableDatasheet
TRM-PGA
process NDIR gas analyzer · rack / wall
L2 · field instrument1–7 gases per heated stainless cuvette · no moving partsCO₂ · CO · CH₄ · SF₆ · N₂O · SO₂ · C₂H₄ · NH₃ · biogas — ppm → 100 vol%LOD < 2 % FS · linearity ±2 % · T90 < 30 s · cross-sens. < 4 %RS-485 Modbus RTU · Ethernet Modbus TCP · USB service · µSD logTRM-PGA-R 19″ 3U Rittal Ripac · TRM-PGA-W Rittal AX 500×500×210 IP66record per unit, traceableDatasheet Manual
IR·SF₆
stationary NDIR transmitter
L2 · field instrumentSF₆ + refrigerants (F-gas)0–1000 / 0–2000 ppm (0–6000 / 0–12000 mg/m³)warm-up 60 s · t₉₀ ≤15 sRS-485 Modbus RTUIP65 · −40…+60 °C · aluminiumrecord per unit, traceableDatasheet Manual
TRM-EX
stationary field gas analyzer · Ex
L2 · field instrumenttoxic · combustible (%LEL) · O₂ · CO₂ · HC · refrigerantsTRM-EX-E · TRM-EX-CT · TRM-EX-IR · TRM-EX-SMC4–20 mA · RS-485 Modbus RTU · relay opt.IP65 · SS316 sensor · −40…+60 °C · 12–24 V DCrecord per unit, traceableDatasheet Manual
GDC
gas detection controller · cabinet
L3 · systemmulti-level gas monitoring & alarm controllerup to 30 analyzers per cabinetModbus RTU / TCP/IP · IEC 60870-5-104600×600×250 mm · 26 kg · IP65 · 230 V ACrecord per unit, traceableDatasheet Manual
GDC-S52
sample-extraction system · GDC family
L3 · systemsequential aspiration of gas samples from remote points to one analyzerup to 12 impulse lines · 8 mm PU tube · 20 m/sModbus TCP · IEC 60870-5-104 (PRP) · RS-485 Modbus RTU1000×600×250 mm · 25 kg · IP65 · −40…+60 °C · dual feed ATSrecord per unit, traceableDatasheet Manual
GASPOD
automated gas-cylinder cabinet
L3 · systemsafe storage & supply of inert · flammable · toxic gasesIP54 · 2550×610×610 mm · up to 4 × 50 L · 300 barModbus TCP (Ethernet) · discrete I/OIP54 · 2550×610×610 mm · up to 4 × 50 L · 300 barDatasheet
Get a quote