IR·OEM
Your instrument. Our NDIR channel.

A calibrated NDIR sensing core with an interface contract, built into your analyzer, skid or building-automation product. One gas or several; ppm to 100 vol%; made to spec, no stock item.

ppm → 100 vol%
2-beam + reference
Modbus · UART · CAN · 4–20 mA
calibration record per unit
ShareLinkedInEmailWhatsAppX
NDIR principle
Specifications

Typical values from the datasheet; accuracy applies under the datasheet's reference conditions. Where a value depends on the application it is specified per project and fixed in the order confirmation.

gasesCO₂ · CO · CH₄ · C₂H₄ · N₂O · SO₂ · NH₃ · SF₆ · SO₂F₂ · CH₃Br · biogas (CH₄/CO₂)
F-gas / refrigerantsSF₆ · R-134a · R-125 · R-22 · R-227ea · R-407c · R-12 · R-113
rangesCO₂ 100 ppm → 100 vol% · CO 2000 ppm → 100 vol% · CH₄ 2000 ppm → 100 vol% · SF₆ 50 ppm → 100 vol% · N₂O / SO₂ / C₂H₄ / NH₃ 200 ppm → 1 vol%
optics2-beam + reference channel · heated cell · T · P · H₂O compensation
performanceLOD 2 % FS · linearity ±2 % · T90 < 30 s · cross-sensitivity < 4 %
interfaceModbus RTU / TCP · Ethernet · UART · RS-232/485 · CAN · LoRa · 4–20 mA
calibrationtraceable ISO 17025 method · VSL · record per unit
not NDIRO₂ · H₂ · N₂ → electrochemical / thermocatalytic channels of TRM-EX
Downloads

Open links — no form.

DocumentFileType
Channel specificationissued per project after the spec callPDF
Interface contract (Modbus / UART / CAN)with the prototypePDF
Calibration recordper unit, traceable to national standardsPDF
Applications and the rule behind each
  • Biomethane digester & grid injection (CH₄ + CO₂)
  • CEMS channels inside third-party analyzers
  • Refrigerant / SF₆ leak detectors for OEMs
  • Indoor-air-quality CO₂ modules for building automation
  • Fumigation clearance instruments (SO₂F₂, CH₃Br)
Gases

Each gas has a reference page with limits, IR band and monitoring practice.

Certificates and compliance

Status words as on the datasheet: certified · pending · application dependent.

CE (EMC, LVD)application dependent — declared with the host instrument
ISO 17025-method calibrationper unit, traceable to VSL
How you get it
1
gas · range · matrix (tap-form below)
2
feasibility & quote in 24 h
3
prototype channel with calibration record
4
series supply with interface contract
FAQ
Board, module or transmitter?
All three: a bare OEM board with UART/Modbus, a benched module with gas fittings, or a housed transmitter with 4–20 mA. Same NDIR core, same calibration record.
Which gases can it not do?
O₂, H₂, N₂, Cl₂ (no usable IR absorption) — those go to electrochemical or catalytic channels in the TRM-EX. H₂S in wet gas is masked by water vapour.
Minimum order?
Prototype channel first (single unit with calibration record), then series; volume bands are agreed per project.
How long does a prototype take?
Typically weeks, not months — confirmed in the quote; it depends on gas, range and enclosure.
Get a quote

Tell us what you measure — just tap

Three taps and an email. An engineer replies within 24 h with feasibility and a price indication.

1 · Which gas?
2 · What for?
3 · What form?
4 · Where do we reply?
Goes to sales@tremon.nl. No newsletter, no tracking.
All products

Full catalogue: channel → instrument → system → · Compare table →

Request a quote →